ELECTRICAL CONNECTIONS
Connect black power cord as follows:
Red wire connects to 8amp fuse then to battery (+) hot.
White wire connects to battery (-) ground.
Blue wire connects to 8 amp fuse, to ignition switch, then to battery (+) switched.
OPERATION
The off timer begins accumulating time when the ignition switch closes. When the off timer reaches
the preset value the pump will turn on. The pump remains activated for the period of time that is
preset on the ON timer.
Remove Access Sealing Plug on front of pump to access manual lube switch, timer adjustments or
to view the system LED’s.
When switching off the ignition voltage and/or the operating voltage the time already used is saved
for an unlimited duration.
When the power supply is switched on again the printed circuit board continues to operate from the
point where it had been interrupted.